Customization: | Available |
---|---|
Direction: | Left to Right |
Transport Package: | Ctns |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The AK-200FC series Gas detector has been designed and built according to European regulations to detect,through the built-in catalytic sensor,the presence of Methane and LPG gas.The sensor is calibrated to detect a gas concentration at 10%of L.E.L.At the same time it ensures a high selectivity with regard to the interfering species usually present in household environments and that could often cause false alarms (cooking steams,wines,alcohol cleaners,ammonia,etc.).
A series of technical features make this detector extremely versatile,reliable,accurate,and safe.
The internal jumper makes it possible to select the relay impulse functioning to connect manual reset solenoid valves,or the continuous functioning to activate solenoid valves and/or sirens.
The relay,free of voltage,allows installation of multiple detectors on a single solenoid valve ensuring control of multiple dangerous environments.Beyond the main alarm signal two pre-alarms were fitted.These are designed to advise the user earlier if compared to other standard detectors.The device is complete with a special circuit that controls the catalytic sensor's efficiency level,and signals any possible fault.The external container has an IP42 protection degree.These features make the Gas Detector reliable for civil environment safety
1. Gas detected:Natural Gas /LPG /liquefied petroleum
gas/Propane and etc.
2. Start warm-up current:≤60MA
3. Working voltage:6VDC
4. Static current:≤40MA
5. Alarm current:≤150MA
6. Static consume:<1W
7. Alarm consume<3W
8. Alarm volume:≥90dB
9. Sensor with high stability and low power consumption
10. Additional function:can work with solenoid valve or
manipulator (optional)
11. Support Exhaust Fan (optional)
12. Working environment:
13. Humidity:≤97%RH Temperature:-5ºC-60ºC
14. Dimensions:120mm*70mm*45mm
15. Power supply
o AC220V/AC230V/AC240V,
o AC110V,
o DC12V
16. Networking:wired networking (NO,NC)(optional)
17. Wireless networking mode:
o 315MHZ/433MHZ (2262 OR 1527)(optional)
18. Alarm density:
o Coal gas:1000~5000ppm
o Liquid petroleum gas:1000~5000ppm
o Natural gas:1000ppm~5000ppm
19. Responding time:≤30s
20. Alarm Output:
o normally open and closed signal,
o control exhaust fan,
o electrical magnetic valve signal.
o In case AC power power-off,the detector will
close the solenoid valve automaticlly
Certificate: CE,EN50194
ISO9001:2000 IP rate:IP42